● UPS power test; generator test; standard test; energy consumption test; data center test; load test; PUE test; charging pile test; battery test; business expansion supporting test
● Industrial parks; ship power stations; power transmission and distribution; new energy fields; smart grids; research institutes; others can be customized
Device model | - | |
Device parameters | Load type | Resistive |
Rated power | 360kw | |
Rated voltage | - | |
Rated current | - | |
Auxiliary power | - | |
Power Factor | PF=1.0 | |
Gear adjustment | - | |
Minimum adjustment gear | - | |
* The above parameters can be customized on demand, please consult online customer service for details | ||
equipment performance | Load deviation | 3% |
Insulation class | F degree | |
degree of protection | IP30 | |
noise at work | <80dB | |
the accuracy | 0.50% | |
Data display | Voltage, Current, Power Factor, Frequency | |
Technical Parameters | Technical features | Load adjustable, sudden loading and unloading functions |
Working mode | continue | |
control mode | local manual | |
cooling mode | Forced air cooling | |
Wind in and out | bottom side intake, the top outlet | |
testing report | No | |
Protective function | 1. Emergency stop: It can be manually unloaded with one key, and cannot be loaded with Emergency Stop locked 2. Short circuit protection: MCB protection 3. Temperature protection: When the load temperature exceeds the safety threshold, it will automatically unload and alarm 4. Fan thermal overload protection: When the fan cannot operate normally, it will automatically unload and alarm | |
connection method | Wiring method | Three-phase Three wire system |
Main circuit | Copper row (with M12 bolts) | |
Control loop | Terminal block | |
Remote communication | No | |
Appearance parameters | Exterior color | RAL7035 industrial gray |
Equipment size | --mm(D)×-mm(W)×-mm(H) | |
Equipment weight | -kg | |
Way of moving | Fixed | |
environmental conditions | Use environment | Indoor - well ventilated | Outdoor(not load in rain day) |
Storage environment | Indoor - no rain environment |
configuration | optional parameters | |||||
Load type | ☑ DC ☑ Resistance ☑ RC ☑ Pure resistive ☑ AC ☑ Single-phase AC ☑ Three phase AC | |||||
Rated power | ☑ active power_____kw ☑ reactive power_____KVA ☑ other(Customized on demand) | |||||
Power Factor | ☑ 0.8 ☑ 1.0 ☑ other(Customized on demand) | |||||
Frequency | ☑ 50HZ ☑ 60HZ ☑ other(Customized on demand) | |||||
Adjustment accuracy | ☑ _____KW,_____A,_____Ω ☑ other(Customized on demand) | |||||
Rated voltage | AC:☑ 110V ☑ 220V ☑ 400V ☑ 690V ☑ 6.3KV ☑ 10.5KV ☑ other(Customized on demand) DC:☑ 100V ☑ 200V ☑ 400V ☑ 600V ☑ 750V ☑ 1.0KV ☑ other(Customized on demand) ☑ other(Customized on demand) | |||||
Way of moving | ☑ fixed ☑ mobile | |||||
Wiring method | ☑ single-phase two-wire ☑ Three-phase three-wire ☑ Three-phase four-wire ☑ other | |||||
Control method | ☑ local manual control ☑ touch screen control ☑ Remote intelligent control ☑ switch control ☑ remote control box ☑ Remote host computer control ☑ control console ☑ other | |||||
Note: If you need to add a logo or other selection configuration, you can consult customer service online |
● The operation is simple, convenient and easy to use, with indicator light; emergency stop button; control switch; adjustable gear switch.
● Wide range of applications; with sudden loading and unloading functions.
● Baking varnish cabinet, a variety of models and styles are available, and can be customized on demand.
● All accessories use first-line brand components, such as: ABB, Siemens, Chint, Schneider, Omron.
● With a professional technical team and design and development team, the line wiring is clear and tidy, and the wiring process is fine (for details, please view the product video).
● Load adjustable, there are four major systems: control system; cooling system; load system; protection system.
● Multilingual operation interface, multiple languages can be selected.
● A variety of control methods can be selected (customized on demand): local manual control; touch screen control; remote intelligent control; switch control; remote control box; remote host computer control.
● Reasonable design, safe and stable, long-term load is not hot; adapt to the host computer software; automatic load balancing.
● Forced cold air, fan heat dissipation, commonly used cooling methods are: bottom air inlet and upper air outlet, side air inlet and side air outlet.
● Commonly used protection functions include: over temperature sound and light alarm; over temperature sound and light alarm and automatic unloading; fuse; emergency stop switch.
● The display function is complete, and the data that can be displayed include: voltage; current; power; frequency; power factor.